7. VPLEX Metro实施步骤

7.1 VPLEX 前期准备

7.1.1 system volumes

VPLEX的system volumes分为两种:metadata volumes 和 logging volumes

7.1.2 meta data volumes

meta data volumes里包含VPLEX cluster的系统配置信息,主要为:

 virtual-to-physical mapping information

 data about the devices and virtual volumes

 system configuration settings

Meta data volume建议为Raid1或者Raid5保护的卷,其对I/O性能的要求不高。

每个VPLEX Metro cluster安装需要4个78GB的volume,分别用于meta-volume, mirrored copy of meta-volume, backups of meta-volume and mirrored-meta-volume.

7.1.3 logging volumes

Loggging volume用于在inter-link断开时,记录Site之间的数据差异索引。建议logging volumes为10GB的volume,10GB的logging volume通常可以支持约320TB的分布式卷。

7.2 Switch zoning

按照规划完成VPLEX backend zoning

7.3 Backend storage provisionq

Register VPLEX BE port on HP3PAR

Assign volume to VPLEX

7.4 VPLEX initial setup

7.4.1 Configip address and hostname of VPLEX

7.4.1.1 Connect to management server

connectEthernet cable to the service port of mgmt server. Config your NIC use DHCP, ip address will be assigned in the range 128.221.252.<23-30>

Default user/password :service/Mi@Dim7T

Service port IP: 128.221.252.2

SSH client: SecureCRT or PUTTY

7.4.1.2 entering the VPLEXCLI

7.4.1.3 set the management server ipaddress

7.4.1.4 change the hostname of VPLEX

7.4.1.5 check software version

7.4.2 use EZ-setup to initialize the VPLEX1

7.4.2.1 Start EZ-setup

7.4.2.2 Configure the first cluster

7.4.2.3 Chose the local authentication

7.4.2.4 Configure event notification

7.4.2.5 Configure send system report to EMC

7.4.2.6 Configure performance statistics collector

7.4.2.7 Generate the certificate

7.4.2.8 Backend storage discovery

1) display eligible meta data volumes

7.4.2.9 create meta-data volume

7.4.2.10 verify if meta-data volume is successfully created

7.4.2.11 create meta-data volume backups

7.4.2.12 enable FE port

7.4.3 use EZ-setup to initialize the VPLEX2

7.4.3.1 Connect to VPLEX2

Use SSH to connect to management IP of cluster 2,

7.4.3.2 Sychronize the time on the clusters

7.4.3.3 Start EZ-setup on cluster2

7.4.3.4 Configure the Meta-data volume and backup of VPLEX2

Use the same method to configure the VPLEX2 meta-data volumes and backups

7.4.3.5 Complete configuration of cluster1

7.4.3.6 Complete configuration of cluster2

7.4.4 Join the clusters

From Vplexcli on cluster2 console, run the following command,

7.4.5 Create logging volumes

7.5 Check the cluster health

7.6 VPLEX backend storage connectivity verify

7.7 Claim the data volume

 check if VPLEX can see the backend arrays

 check backend volumes

 if can not see the volumes, use command to re-discover

 claim the data volumes

Claim by use parameter “--appc” to ensure application consistency, because we have data on one leg of the mirror.

8. 设备的使用

8.1 Vplex的使用

使用英文版的Web browser: Firefox v3.5.5 or v3.5.7, or Internet Explorer 7(安装Adobe Flash Player 10.0.0 or higher插件)输入https://设备管理IP

9. 系统测试

9.1 Vplex高可用测试

a) 测试场景一:主机的一个光纤卡故障

b) 测试场景二: VPLEX的一个Director故障

c) 测试场景三: VPLEX后端存储的一个控制器故障

d) 测试场景四: VPLEX后端一台存储故障

9.2 数据库高可用测试

e) 测试场景一:主机的一个光纤卡故障

f) 测试场景二: VPLEX的一个Director故障

g) 测试场景三: VPLEX后端存储的一个控制器故障

h) 测试场景四: VPLEX后端一台存储故障

i) 测试场景四: VPLEX后端一台存储故障



EMC存储,戴尔dell存储,戴尔dell服务器,戴尔dell工作站,戴尔dell刀片服务器,戴尔dell磁盘阵列存储,戴尔服务器,武汉戴尔服务器,戴尔 R930,戴尔 R730,武汉戴尔存储,武汉戴尔工作站 Keywords: EMC存储 戴尔dell存储 戴尔dell服务器 戴尔dell工作站 戴尔dell刀片服务器 戴尔dell磁盘阵列存储 中粮礼品卡 有声小说 尤克里里 广赢投资管理有限公司 海外学历认证 成都茶叶包装设计 中部微交易 常州英语翻译 天津景观设计 泰国货运 广州黑老头传媒 成都商务光纤 天堂鸟影视网 银河微盘 java培训 派工管理软件 外汇EA 山东专升本 移动警务系统 宏观经济管理 小学科学实验 烟台商标注册 伦敦黄金 杭州围棋培训班 天气数据api接口 昆山外资公司注册 众筹 大连认证 上海造价 微商协会 合肥别墅庭院设计 上海房产纠纷律师 京广视讯网 哈比桥治幼儿园 票据律师 北京app制作 瞬营销手机 催眠大师